Our CWBSP training materials have been honored as the panacea for the candidates for the exam since all of the contents in the CWBSP guide quiz are the essences of the exam. There are detailed explanations for some difficult questions in our CWBSP exam practice. Consequently, with the help of our CWBSP Study Materials, you can be confident that you will pass the exam and get the related certification as easy as rolling off a log. So what are you waiting for? Just take immediate actions!
Topic | Details |
---|---|
Topic 1 |
|
Topic 2 |
|
Topic 3 |
|
Topic 4 |
|
We provide 24-hour online service for all customers who have purchased CWBSP test guide. You can send us an email to ask questions at anytime, anywhere. For any questions you may have during the use of CWBSP exam questions, our customer service staff will be patient to help you to solve them. At the same time, if you have problems with downloading and installing, CWBSP Torrent prep also has dedicated staff that can provide you with remote online guidance. In order to allow you to use our products with confidence, CWBSP test guide provide you with a 100% pass rate guarantee. Once you unfortunately fail the exam, we will give you a full refund, and our refund process is very simple.
NEW QUESTION # 51
An office space with 10 ft (3 m) high ceilings is designated as a Light Hazard Occupancy. It is determined that the area of sprinkler operation is 1,500 ft2 (139 m2). Assuming the conditions are satisfied for design area reduction, what can the area of sprinkler operation be reduced to for quick response sprinklers?
Answer: D
Explanation:
NFPA 13 allows for a reduction in the design area for quick-response sprinklers under certain conditions, such as in light hazard occupancies with ceilings not exceeding 12 ft in height. A reduction to 1,100 ft² is consistent with the allowance for using quick-response sprinklers to cover a smaller area more effectively due to their faster activation in fire scenarios.
References: NFPA 13 guidelines on the application and benefits of quick-response sprinklers in various occupancy types, including light hazard areas.
NEW QUESTION # 52
A device for use in applications requiring special water discharge patterns, directional spray, or other unusual discharge characteristics, is known as a
Answer: B
Explanation:
A special sprinkler is a device for use in applications requiring special water discharge patterns, directional spray, or other unusual discharge characteristics, as defined by NFPA 13. Examples of special sprinklers include residential sprinklers, exposure protection sprinklers, water curtains, and sprinkler-protected glazing.
Special sprinklers have different design and installation requirements than standard spray sprinklers.
References: NFPA 13, 2019 edition, section 3.3.27.1; NFPA 13 Handbook, 2019 edition, page 31.
A special sprinkler is designed for specific applications that require unique water discharge patterns, directional spray, or other specialized discharge characteristics. These sprinklers are tailored for particular fire risks or architectural constraints where standard sprinklers may not provide adequate protection.
References: NFPA 13's definitions and classifications of sprinklers, including special sprinklers for unique fire protection challenges.
NEW QUESTION # 53
An existing sprinkler system in a 25 ft (1.5 m) tall building is found to be designed using K-8.0 (115) high temperature control mode density/area (CMDA) sprinklers with a design criteria of 0.35 gpm/ft2 (13.3 mm/min) over
2000 ft2 (186 m2). What is the maximum storage height permitted for double-row rack storage with 8 ft (2.4 m) aisles of a nonencapsulated Class IV commodity?
Answer: A
Explanation:
The maximum storage height permitted for double-row rack storage of a nonencapsulated Class IV commodity with the specified design criteria would likely be around 16.5 feet. This takes into account the density and area coverage required for protecting Class IV commodities.
References: NFPA 13 provides guidelines for storage arrangements, including maximum storage heights and design criteria based on commodity classifications.
NEW QUESTION # 54
In a three-story apartment building protected with an NFPA 13R system utilizing quick-response sprinklers, the minimum density/area requirement shall be?
Answer: D
Explanation:
In a three-story apartment building protected with an NFPA 13R system utilizing quick-response sprinklers, the minimum density/area requirement is typically 0.10 gpm/ft². This density ensures adequate coverage for residential occupancies with a moderate level of combustibles.
References: NFPA 13R specifies requirements for the design and installation of sprinkler systems in residential occupancies up to four stories in height, including minimum density requirements.
NEW QUESTION # 55
What is the hose stream allowance and duration for rolled paper storage protected using ESFR sprinklers?
Answer: B
Explanation:
ESFR (Early Suppression, Fast Response) sprinklers are designed for high-challenge fire hazards like rolled paper storage. The hose stream allowance for such systems is typically higher to account for the potential need for manual firefighting assistance. 500 gpm for 120 minutes provides a substantial water supply for this purpose.
References: Based on NFPA 13's guidelines for storage and ESFR sprinkler systems.
NEW QUESTION # 56
......
Have you ever noticed that people who prepare themselves for NFPA CWBSP certification exam do not need to negotiate their salaries for a higher level, they just get it after they are NFPA CWBSP Certified? The reason behind this fact is that they are considered the most deserving candidates for that particular job.